Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Anal Bioanal Chem ; 413(22): 5619-5632, 2021 Sep.
Article in English | MEDLINE | ID: covidwho-2174032

ABSTRACT

In the face of the COVID-19 pandemic, the need for rapid serological tests that allow multiplexing emerged, as antibody seropositivity can instruct about individual immunity after an infection with SARS-CoV-2 or after vaccination. As many commercial antibody tests are either time-consuming or tend to produce false negative or false positive results when only one antigen is considered, we developed an automated, flow-based chemiluminescence microarray immunoassay (CL-MIA) that allows for the detection of IgG antibodies to SARS-CoV-2 receptor-binding domain (RBD), spike protein (S1 fragment), and nucleocapsid protein (N) in human serum and plasma in less than 8 min. The CoVRapid CL-MIA was tested with a set of 65 SARS-CoV-2 serology positive or negative samples, resulting in 100% diagnostic specificity and 100% diagnostic sensitivity, thus even outcompeting commercial tests run on the same sample set. Additionally, the prospect of future quantitative assessments (i.e., quantifying the level of antibodies) was demonstrated. Due to the fully automated process, the test can easily be operated in hospitals, medical practices, or vaccination centers, offering a valuable tool for COVID-19 serosurveillance. Graphical abstract.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing/methods , Immunoassay/methods , Immunoglobulin G/blood , SARS-CoV-2/immunology , Antigens, Viral/chemistry , Antigens, Viral/immunology , Automation, Laboratory , Coronavirus Nucleocapsid Proteins/immunology , Humans , Immobilized Proteins/chemistry , Immobilized Proteins/immunology , Immune Sera , Immunoassay/instrumentation , Lab-On-A-Chip Devices , Luminescent Measurements , Phosphoproteins/immunology , Sensitivity and Specificity , Spike Glycoprotein, Coronavirus/genetics , Spike Glycoprotein, Coronavirus/immunology , Time Factors
2.
Pharmaceuticals (Basel) ; 15(2)2022 Feb 02.
Article in English | MEDLINE | ID: covidwho-1674755

ABSTRACT

Despite numerous advances in personalized phage therapy, smooth logistics are challenging, particularly for multidrug-resistant Gram-negative bacterial infections requiring high numbers of specific lytic phages. We conducted this study to pave the way for efficient logistics for critically ill patients by (1) closely examining and improving a current pipeline under realistic conditions, (2) offering guidelines for each step, leading to safe and high-quality phage supplies, and (3) providing a tool to evaluate the pipeline's efficiency. Due to varying stipulations for quality and safety in different countries, we focused the pipeline on all steps up to a required phage product by a cell-free extract system. The first of three study runs included patients with respiratory bacterial infections from four intensive care units, and it revealed a cumulative time of up to 23 days. Ultimately, adjustment of specific set points of the vulnerable components of the pipeline, phage isolation, and titration increased the pipeline's efficiency by 15% and decreased the maximum required time to 13 days. We present a site-independent practical approach to establish and optimize pipelines for personalized phage delivery, the co-organization of pipeline components between different institutions, non-binding guidelines for every step, and an efficiency check for phage laboratories.

3.
JMIR Form Res ; 6(1): e32564, 2022 Jan 04.
Article in English | MEDLINE | ID: covidwho-1528774

ABSTRACT

BACKGROUND: Large-scale, polymerase chain reaction (PCR)-based SARS-CoV-2 testing is expensive, resource intensive, and time consuming. A self-collection approach is a probable alternative; however, its feasibility, cost, and ability to prevent infections need to be evaluated. OBJECTIVE: This study aims to compare an innovative self-collection approach with a regular SARS-CoV-2 testing strategy in a large European industrial manufacturing site. METHODS: The feasibility of a telemedicine-guided PCR-based self-collection approach was assessed for 150 employees (intervention group) and compared with a regular SARS-CoV-2 testing approach used for 143 employees (control group). Acceptance, ergonomics, and efficacy were evaluated using a software application. A simulation model was implemented to evaluate the effectiveness. An interactive R shiny app was created to enable customized simulations. RESULTS: The test results were successfully communicated to and interpreted without uncertainty by 76% (114/150) and 76.9% (110/143) of the participants in the intervention and control groups, respectively (P=.96). The ratings for acceptability, ergonomics, and efficacy among intervention group participants were noninferior when compared to those among control group participants (acceptability: 71.6% vs 37.6%; ergonomics: 88.1% vs 74.5%; efficacy: 86.4% vs 77.5%). The self-collection approach was found to be less time consuming (23 min vs 38 min; P<.001). The simulation model indicated that both testing approaches reduce the risk of infection, and the self-collection approach tends to be slightly less effective owing to its lower sensitivity. CONCLUSIONS: The self-collection approach for SARS-CoV-2 diagnosis was found to be technically feasible and well rated in terms of acceptance, ergonomics, and efficacy. The simulation model facilitates the evaluation of test effectiveness; nonetheless, considering context specificity, appropriate adaptation by companies is required.

4.
Infection ; 49(5): 927-934, 2021 Oct.
Article in English | MEDLINE | ID: covidwho-1384715

ABSTRACT

PURPOSE: To evaluate the diagnostic reliability and practicability of self-collected oropharyngeal swab samples for the detection of SARS-CoV-2 infection as self-sampling could enable broader testing availability and reduce both personal protective equipment and potential exposure. METHODS: Hospitalized SARS-CoV-2-infected patients were asked to collect two oropharyngeal swabs (SC-OPS1/2), and an additional oropharyngeal swab was collected by a health care professional (HCP-OPS). SARS-CoV-2 PCR testing for samples from 58 participants was performed, with a 48-h delay in half of the self-collected samples (SC-OPS2). The sensitivity, probability of concordance, and interrater reliability were calculated. Univariate and multivariate analyses were performed to assess predictive factors. Practicability was evaluated through a questionnaire. RESULTS: The test sensitivity for HCP-OPS, SC-OPS1, and SC-OPS2 was 88%, 78%, and 77%, respectively. Combining both SC-OPS results increased the estimated sensitivity to 88%. The concordance probability between HCP-OPS and SC-OPS1 was 77.6% and 82.5% between SC-OPS1 and SC-OPS2, respectively. Of the participants, 69% affirmed performing future self-sampling at home, and 34% preferred self-sampling over HCP-guided testing. Participants with both positive HCP-OPS1 and SC-OPS1 indicating no challenges during self-sampling had more differences in viral load levels between HCP-OPS1 and SC-OPS1 than those who indicated challenges. Increasing disease duration and the presence of anti-SARS-CoV-2-IgG correlated with negative test results in self-collected samples of previously confirmed SARS-CoV-2 positive individuals. CONCLUSION: Oropharyngeal self-sampling is an applicable testing approach for SARS-CoV-2 diagnostics. Self-sampling tends to be more effective in early versus late infection and symptom onset, and the collection of two distinct samples is recommended to maintain high test sensitivity.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19 Testing , Health Personnel , Humans , Reproducibility of Results
5.
Respir Res ; 22(1): 119, 2021 Apr 23.
Article in English | MEDLINE | ID: covidwho-1202183

ABSTRACT

BACKGROUND: In the absence of PCR detection of SARS-CoV-2 RNA, accurate diagnosis of COVID-19 is challenging. Low-dose computed tomography (CT) detects pulmonary infiltrates with high sensitivity, but findings may be non-specific. This study assesses the diagnostic value of SARS-CoV-2 serology for patients with distinct CT features but negative PCR. METHODS: IgM/IgG chemiluminescent immunoassay was performed for 107 patients with confirmed (group A: PCR + ; CT ±) and 46 patients with suspected (group B: repetitive PCR-; CT +) COVID-19, admitted to a German university hospital during the pandemic's first wave. A standardized, in-house CT classification of radiological signs of a viral pneumonia was used to assess the probability of COVID-19. RESULTS: Seroconversion rates (SR) determined on day 5, 10, 15, 20 and 25 after symptom onset (SO) were 8%, 25%, 65%, 76% and 91% for group A, and 0%, 10%, 19%, 37% and 46% for group B, respectively; (p < 0.01). Compared to hospitalized patients with a non-complicated course (non-ICU patients), seroconversion tended to occur at lower frequency and delayed in patients on intensive care units. SR of patients with CT findings classified as high certainty for COVID-19 were 8%, 22%, 68%, 79% and 93% in group A, compared with 0%, 15%, 28%, 50% and 50% in group B (p < 0.01). SARS-CoV-2 serology established a definite diagnosis in 12/46 group B patients. In 88% (8/9) of patients with negative serology > 14 days after symptom onset (group B), clinico-radiological consensus reassessment revealed probable diagnoses other than COVID-19. Sensitivity of SARS-CoV-2 serology was superior to PCR > 17d after symptom onset. CONCLUSIONS: Approximately one-third of patients with distinct COVID-19 CT findings are tested negative for SARS-CoV-2 RNA by PCR rendering correct diagnosis difficult. Implementation of SARS-CoV-2 serology testing alongside current CT/PCR-based diagnostic algorithms improves discrimination between COVID-19-related and non-related pulmonary infiltrates in PCR negative patients. However, sensitivity of SARS-CoV-2 serology strongly depends on the time of testing and becomes superior to PCR after the 2nd week following symptom onset.


Subject(s)
COVID-19/blood , COVID-19/diagnostic imaging , Adolescent , Adult , Aged , Aged, 80 and over , Algorithms , Critical Care/statistics & numerical data , Female , Hospitalization/statistics & numerical data , Humans , Immunoglobulin G/analysis , Immunoglobulin M/analysis , Male , Middle Aged , Pandemics , Polymerase Chain Reaction , Retrospective Studies , Seroconversion , Serologic Tests , Tomography, X-Ray Computed , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL